Dell Networking S4128T-ON Switch
Call for price and availability
- 100% Dell Original Components
- 30-Day Money Back Guarantee
- Dell Engineer Approved
- Ports:1/10GbE Base-T
- Primary Port Quantity:28 ports
- Uplink Ports:100GbE QSFP28
- Uplink Port Quantity:2 ports
- Hot-swappable AC Power Supply:redundant 550W
- Networking Model:S4128T-ON
- Airflow:Standard Airflow / Reverse Airflow
- Default Operation System:Dell OS10 Enterprise
- PoE:NO
- Power Supply:2 x redundant, hot-swappable 550W AC PSUs
- Transceivers:Not included
SKU: >S4128T-ON
Resources
Tech Specs
-
Switch Features:
S4128T, 28x 10GBASE-T, 2x 100GbE QSFP28, 2x AC PSU, 4x Fan module, I/O Panel to PSU Airflow
S4128T, 28x 10GBASE-T, 2x 100GbE QSFP28, 2x AC PSU, 4x Fan module , PSU to I/O Panel Airflow -
Physical:
1 RJ45 console/management port with RS232 signaling
1 RJ45 micro-USB-B console port
1 RJ45 10/100/1000Base-T management Ethernet port
Hot swappable redundant power
Hot swappable redundant fans -
Chassis:
Size: 1 RU, 1.75”(h) x 17”(w) x 18”(d) (4.4cm (h) x 43.1cm (w) x 45.7cm (d))
-
Environmental:
Power supply: 100–240 VAC 50/60 Hz Max. current draw per system: 6A/5A at 100/120V AC; 3A/2.5A at 200/240V AC
Max. operating specifications: Operating temperature: 32° to 104° F (0° to 40°C) designed to ensure consistent functionality in moderate temperature conditions
Operating humidity: 5 to 85% (RH), non-condensing
Max. non-operating specifications: Storage temperature: -40° to 149°F (-40° C to 65° C)
Storage humidity: 5 to 95% (RH), non-condensing
Operational altitude: -100 feet BMSL to 10,000 feet
Storage altitude: -100 feet BMSL to 15,000 feet -
Redundant Power Supplies (Not Applicable to S4112):
S4100, AC Power Supply, IO Panel to PSU Airflow AC Power Supply, PSU to IO Panel Airflow DC Power Supply, IO Panel to PSU Airflow DC Power Supply, PSU to IO Panel Airflow HV DC Power Supply, IO Panel to PSU Airflow HV DC Power Supply, PSU to IO Panel Airflow
-
Transceiver Optics (Optional):
10GbE, SR SFP+, short reach
10GbE, LR SFP+, long reach
10GbE, ER SFP+, extended reach
10GbE, ZR SFP+ extra extended reach 10G,
10GbE, USR, SFP+
10GBASE-T use with QSA in QSFP+ port, 30m reach on CAT6a/7
40GbE, SR4 optic QSFP+
40GbE, eSR4 optic QSFP+
40GbE, LR4 optic QSFP+
40GbE, ER4 optics QSFP+
40GbE, PSM4-LR MPO 10Km QSFP+ to LC
40GbE, LM4 / SM4 Duplex QSFP+
100GbE, SR4 QSFP28
100GbE, LR4 QSFP28
100GbE, LR4Lite QSFP28
100GbE, CWDM4 2Km QSFP28
100GbE, PSM4 500m QSFP28
100GbE, PSM4-IR, QSFP28 -
Cables (Optional):
40GbE, QSFP+ to QSFP+, active optical
40GbE, QSFP+ to QSFP+, passive DAC
40GbE, MTP to 4xLC optical breakout
40GbE, 4x10GbE, QSFP+ to 4xSFP+, passive DAC
100GbE, 4x25GbE, QSFP28 to 4xSFP28, passive DAC
100GbE, QSFP28 to QSFP28, active optical
100GbE, QSFP28 to QSFP28, passive DAC
100GbE, 2x50GbE, QSFP28 to 2xQSFP28, passive DAC -
Regulatory Compliance:
EN 300 386 V1.4.1:2008 EMC for Network Equipment
EN 55024: 1998 + A1: 2001 + A2: 2003
EN 61000-3-2: Harmonic Current Emissions
EN 61000-3-3: Voltage Fluctuations and Flicker
EN 61000-4-2: ESD
EN 61000-4-3: Radiated Immunity
EN 61000-4-4: EFT
EN 61000-4-5: Surge
EN 61000-4-6: Low Frequency Conducted Immunity -
Safety and emissions:
UL/CSA 60950-1, Second Edition
EN 60950-1, Second Edition
IEC 60950-1, Second Edition Including All National Deviations and Group Differences
EN 60825-1 Safety of Laser Products Part 1: Equipment Classification Requirements and User’s Guide
EN 60825-2 Safety of Laser Products Part 2: Safety of Optical Fibre Communication Systems
FDA Regulation 21 CFR 1040.10 and 1040.11
Australia/New Zealand: AS/NZS CISPR 32: Class A
Canada: ICES-003, Issue-4, Class A
Europe: EN 55032: 2015+A1:2007 (CISPR 32), Class A
Japan: VCCI V3/2009 Class A
USA: FCC CFR 47 Part 15, Subpart B:2009, Class A -
RoHS:
All S-Series components are EU RoHS compliant.